D1000 SERIES |
PSD1001
|
Hazardous Area:
15 V, 20 mA
3-Wires Tx
or other devices
Safe Area: 24 Vdc
Ch.per unit: 4
Supply: 21.5-30 Vdc
|
IEC 61511-SIL 2 Bus powered |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1072S
|
Hazardous Area:
Universal TC,
3/4-Wires RTD,
Potentiometer,
mV
Safe Area:
4-20 mA, 0-20 mA
(source)
or
1-5 V, 0-5 V,
2-10 V, 0-10 V
Ch.per unit: 1
Supply: 10-30 Vdc
|
IEC 61511-SIL 2 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1062S
|
Hazardous Area:
Vibration Transducers,
Accelerometers,
2/3-Wires sensors
Safe Area:
Transparent
input repeater
Ch.per unit: 1
Supply: 20-30 Vdc
|
IEC 61511-SIL 2 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1053S
|
Hazardous Area:
4-20 mA, 0-20 mA
1-5 V, 0-5 V,
2-10 V, 0-10 V
Safe Area:
4-20 mA, 0-20 mA
(source)
or
1-5 V, 0-5 V,
2-10 V, 0-10 V
2 Independent
set points via
2 SPST Relays
Ch.per unit: 1
Supply: 20-30 Vdc
|
IEC 61511-SIL 2 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1044D
|
Hazardous Area:
2 SPDT (relay contact) 2
Safe Area:
Voltage free Contact,
Logic Level,
from DCS, PLC or
other control devices
Bus powered
Ch.per unit: 2
Supply: 20-30 Vdc
|
IEC 61511-SIL 2 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1040Q
|
Hazardous Area:
Electrovalve, Audible
Alarm or other devices
Safe Area:
Voltage free Contact,
Logic Level,
Loop powered 24 Vdc from
DCS, PLC or
other control devices
Ch.per unit: 4
Supply: 21.5-30 Vdc
|
IEC 61511-SIL 2 Bus powered |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1034S
|
Hazardous Area:
Voltage free Contact,
Proximity Switch
Line fault detection
Isolated inputs
Safe Area:
Transparent repeater of
input status
0 to 8 mA range
Ch.per unit: 1
Supply: 10-30 Vdc
|
IEC 61511-SIL 3 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1032D
|
Hazardous Area:
Voltage free Contact,
Proximity Switch
Line fault detection
Isolated inputs
Safe Area:
2 SPST (relay contact)
+ 2 SPST (alarm or duplicator)
+ LED (fault status)
Ch.per unit: 2
Supply: 20-30 Vdc
|
IEC 61511-SIL 2 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1020D
|
Hazardous Area:
4-20 mA
0-20 mA
Analog Signal to I/P
Converters, Electrovalves,
Actuators and Displays
Smart compatible
Safe Area:
4-20 mA
0-20 mA
Bus powered
signal from DCS, PLC or
other control devices.
Ch.per unit: 2
Supply: 20-30 Vdc
|
IEC 61511-SIL 2 |
如需提供其他型号,请联系我们。 |
|
|
D1000 SERIES |
D1010S
|
Hazardous Area:
4-20 mA
0-20 mA
2/3-Wires Tx
Smart compatible
Safe Area:
4-20 mA
0-20 mA
(source or sink)
or
1-5 V
0-5 V
Ch.per unit: 1
Supply: 20-30 Vdc
|
IEC 61511-SIL 3 |
如需提供其他型号,请联系我们。 |
加入询价单
.
|