产品中心 > Thytronic 保护继电器 > Pro-N Intelligent Electronic Devices
产品详细页
询价 图片 产品描述 型号 技术参数 认证 备注
NV11B Multifunction Voltage Relay NV11B
Protection functions
Undervoltage (27)
27.1 - Unipolar undervoltage (27.1)
27.2 - Unipolar undervoltage (27.2)
27.3 - Unipolar undervoltage (27.3)
27.4 - Unipolar undervoltage (27.4)
Overvoltage (59)
59.1 - Unipolar overvoltage (59.1)
59.2 - Unipolar overvoltage (59.2)
59.1 - Unipolar overvoltage (59.3)
Residual overvoltage (59N)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NV10P Multifunction Voltage And Frequency (Pro) NV10P
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Overvoltage (59)
Residual overvoltage (59N)
Frequency rate of change (81R)
Underfrequency & overfrequency (81U 81O)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NV10B Multifunction Voltage And Frequency (Base) NV10B
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Overvoltage (59)
Residual overvoltage (59N)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NTGP Multifunction Protection For Large Size Generators NTGP
Protection functions
Underimpedance (21)
Overflux (V/Hz) (24)
Pt100 thermometric probes (26)
Undervoltage (27)
Third harmonic undervoltage (27H)
Directional active overpower (32P)
Reverse active overpower (32R)
Active underpower (37P)
Loss of field (40)
Negative sequence overcurrent (46)
Thermal image (49)
Inadvertent energizing (50+27)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Voltage-controlled overcurrent (51V)
Overvoltage (59)
Third harmonic overvoltage (59H)
Residual overvoltage (59N)
Rotor earth fault (64F)
Low impedance restricted ground fault (64REF)
Underfrequency & overfrequency (81U 81O)
High impedance restricted earth fault (87NHIZ)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NTGB Multifunction Protection For Small And Medium Size Generators NTGB
Protection functions
Underimpedance (21)
Pt100 thermometric probes (26)
Undervoltage (27)
Reverse active overpower (32R)
Loss of field (40)
Negative sequence overcurrent (46)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Voltage-controlled overcurrent (51V)
Overvoltage (59)
Residual overvoltage (59N)
Underfrequency & overfrequency (81U 81O)
High impedance restricted earth fault (87NHIZ)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NT30 Biased Differential For Two Or Three Sides NT30
Protection functions
Overflux (V/Hz) (24)
Pt100 thermometric probes (26)
Undervoltage (27)
Phase undercurrent (37)
Negative sequence overcurrent (46)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Overvoltage (59)
Residual overvoltage (59N)
Low impedance restricted ground fault (64REF)
Underfrequency & overfrequency (81U 81O)
Differential for transformers, generators, motors, short lines (87)
High impedance restricted earth fault (87NHIZ)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NT20 Biased Differential For Two Or Three Sides NT20
Protection functions
Overflux (V/Hz) (24)
Pt100 thermometric probes (26)
Undervoltage (27)
Phase undercurrent (37)
Negative sequence overcurrent (46)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Overvoltage (59)
Residual overvoltage (59N)
Low impedance restricted ground fault (64REF)
Underfrequency & overfrequency (81U 81O)
Differential for transformers, generators, motors, short lines (87)
High impedance restricted earth fault (87NHIZ)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NT10 Biased Differential For Two Winding Transformers NT10
Protection functions
Pt100 thermometric probes (26)
Phase undercurrent (37)
Negative sequence overcurrent (46)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Low impedance restricted ground fault (64REF)
High impedance restricted earth fault (87NHIZ)
Biased differential for transformer (87T)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NS20 Synchronizing Device NS20
Protection functions
Synchro-check & synchronizing (25)
Pt100 thermometric probes (26)
Undervoltage (27)
Overvoltage (59)
Underfrequency & overfrequency (81U 81O)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NS10 Synchronizing Device NS10
Protection functions
Synchro-check & synchronizing (25)
Pt100 thermometric probes (26)
Voltage and frequency regulator (90V 90F)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NR10 Automatic Reclosing Device NR10
Protection functions
Pt100 thermometric probes (26)
Automatic reclosing (79)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NP10 Power Relay NP10
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Directional active overpower (32P)
Directional reactive overpower (32Q)
Active underpower (37P)
Reactive underpower (37Q)
Power factor (55)
Overvoltage (59)
Residual overvoltage (59N)
Frequency rate of change (81R)
Underfrequency & overfrequency (81U 81O)
Breaker failure (BF)
Vector jump (DPHI)
如需提供其他型号,请联系我们。
NM20 Multifunction Protection Relay NM20
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Direct sequence undervoltage (27V1)
Reverse active overpower (32R)
Phase undercurrent (37)
Active underpower (37P)
Loss of field (40)
Negative sequence overcurrent (46)
Phase reversal (47)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Locked rotor (51LR(48)/14)
Power factor (55)
Overvoltage (59)
Residual overvoltage (59N)
Negative sequence overvoltage (59V2)
Maximum number of starting (66)
Ground directional overcurrent (67N)
Underfrequency & overfrequency (81U 81O)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NM10 Multifunction Protection Relay NM10
Protection functions
Pt100 thermometric probes (26)
Phase undercurrent (37)
Negative sequence overcurrent (46)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Locked rotor (51LR(48)/14)
Maximum number of starting (66)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NG20 Protection Relay NG20
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Reverse active overpower (32R)
Active underpower (37P)
Loss of field (40)
Negative sequence overcurrent (46)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Voltage-controlled overcurrent (51V)
Power factor (55)
Overvoltage (59)
Residual overvoltage (59N)
Underfrequency & overfrequency (81U 81O)
High impedance restricted earth fault (87NHIZ)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NG10 Protection Relay NG10
Protection functions
Pt100 thermometric probes (26)
Residual overcurrent (50N/51N)
Low impedance restricted ground fault (64REF)
Differential protection for generators and motors (87G/87M)
High impedance restricted earth fault (87NHIZ)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NC20 Multifunction Protection Relay NC20
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Phase undercurrent (37)
Neutral unbalance overcurrent with inherent unbalance compensation (46N)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Overvoltage (59)
Breaker failure (BF)
Discharge Timer (TD)
如需提供其他型号,请联系我们。
NC10 Multifunction Protection Relay NC10
Protection functions
Pt100 thermometric probes (26)
Phase undercurrent (37)
Neutral unbalance overcurrent with inherent unbalance compensation (46N)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Breaker failure (BF)
Discharge Timer (TD)
如需提供其他型号,请联系我们。
NA90 Protection Relay NA90
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Overvoltage (59)
Residual overvoltage (59N)
Phase directional overcurrent (67)
Ground directional overcurrent (67N)
Breaker failure (BF)
如需提供其他型号,请联系我们。
NA80 Protection Relay NA80
Protection functions
Pt100 thermometric probes (26)
Undervoltage (27)
Thermal image (49)
Phase overcurrent (50/51)
Residual overcurrent (50N/51N)
Overvoltage (59)
Residual overvoltage (59N)
Phase directional overcurrent (67)
Ground directional overcurrent (67N)
Automatic reclosing (79)
Breaker failure (BF)
如需提供其他型号,请联系我们。
加入询价单 .
相关文件下载
相关链接