Connections:
Relay with NE and ND Coil and Load (1-1 , 0-0).
SIL 3 function NE: disconnect Load by disconnecting input (0-0).
SIL 3 function ND: connect Load by connecting input (1-1).
Rating:
3A
250 Vac 750 VA
3A
125 Vdc 120 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D1093S
Connections:
Dual channel Relay with NE and ND Coil and Load (1-1 , 0-0).
SIL 3 function NE: disconnect Load by disconnecting input (0-0).
SIL 3 function ND: connect Load by connecting input (1-1).
With line and load diagnostic function.
Rating:
3A
250 Vac 750 VA
3A
125 Vdc 120 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D1092S-069
Connections:
Relay with NE Coil and Load (1-1) and ND Coil and NE Load (0-1).
SIL 3 function NE: disconnect Load by disconnecting input (0-0).
SIL 3 function ND: disconnect Load by connecting input (1-0).
Rating:
3A
250 Vac 750 VA
3A
125 Vdc 120 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D1092D
Connections:
Dual channel Relay with NE and ND Coil and Load (1-1 , 0-0).
SIL 3 function NE: disconnect Load by disconnecting input (0-0).
SIL 3 function ND: connect Load by connecting input (1-1).
Can be used to disconnect two loads or both supply lines.
Rating:
3A
250 Vac 750 VA
3A
125 Vdc 120 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D5294S
Connections:
Relay with NE Coil and Load (1-1).
SIL 3 function: disconnect Load by disconnecting input (0-0).
Can be used to disconnect both supply lines (see figures).
With smart line and load diagnostic function. Modbus RS-485 output.
Rating:
10A
250 Vac 2500 VA
10A
250 Vdc 300 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D5290S-084
Connections:
Relay with NE Coil and NE/ND Load for interrupting up to 4 loads.
SIL 3 function: configurable via external wiring. AC Coil.
Can be used to disconnect one or both supply lines (see data sheet).
Rating:
5A
250 Vac 1250 VA
5A
250 Vdc 175 W
110 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D5290S-078
Connections:
Relay for NE/ND Load with NE/ND Coil for interrupting up to 4 loads.
SIL 3 function: configurable via external wiring.
Can be used to disconnect one or both supply lines (see data sheet).
Rating:
5A
250 Vac 1250 VA
5A
250 Vdc 175 W
24 Vdc Coil
IEC 61511-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D5290S
Connections:
Relay with NE Coil and Load (1-1).
SIL 3 function: disconnect Load by disconnecting input (0-0).
Can be used to disconnect one or both supply lines (see figures).
Rating:
10A
250 Vac 2500 VA
10A
250 Vdc 300 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D5091S
Connections:
Relay with ND or NE Coil and ND Load (0-0 or 1-0).
SIL 3 function: connect Load by connecting input (1-1) or
connect Load by disconnecting input (0-1) (see figures).
To disconnect both supply lines, use two D5091S units in parallel.
Rating:
4A
250 Vac 1000 VA
4A
250 Vdc 120 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
High Integrity Safety Relays
D5090S
Connections:
Relay with NE Coil and Load (1-1).
SIL 3 function: disconnect Load by disconnecting input (0-0).
Can be used to disconnect one or both supply lines (see figures).
Rating:
4A
250 Vac 1000 VA
4A
250 Vdc 120 W
24 Vdc Coil
IEC 61508-SIL 3
Other models also available, please contact us for details.
Copyright 2003-2011 (c) Laplace Electric Ltd. ,All rights servered.
Address: Unit C,5/F,Southeast Industrial Building,611-619 Castle Peak Road,Tsuen Wan,N.T. Hong Kong. Tel:852-24131255 Fax:852-24131277 Contacts:Mr. Chris Lau