                                    D5000 SERIESS 
                                    D5014S 
                                    Hazardous Area: 
4-20 mA 
2-Wires 
Active or Passive Tx; 
Smart compatible 
 
Safe Area: 
4-20 mA 
(source or sink) Ch.per unit: 1 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5011S 
                                    Hazardous Area: 
4-20 mA 
2-Wires Tx only; 
Smart compatible 
 
Safe Area: 
4-20 mA 
(source only) Ch.per unit: 1 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5273S 
                                    Hazardous Area: 
Universal TC, 
3/4-Wires RTD, 
Pot, mV 
 
Safe Area: 
4-20 mA (source or sink) 
2 independent set points 
via 1 SPDT Relay each 
+ Modbus Ch.per unit: 1 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 2 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5062S 
                                    Hazardous Area: 
Vibration Transducers, 
Accelerometers, 
2/3-Wires sensors 
 
Safe Area: 
Transparent 
input repeater Ch.per unit: 1 
Supply: 
18-30 Vdc 
                                    IEC 61511-SIL 2 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5034D 
                                    Hazardous Area: 
Voltage free Contact, 
Proximity Switch 
Line fault detection 
Isolated inputs 
 
Safe Area: 
Transparent repeater of 
input status 
0 to 8 mA range Ch.per unit: 2 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS  
                                    D5231E 
                                    Hazardous Area: 
Voltage free Contact, 
Proximity Switch 
Line fault detection 
 
Safe Area: 
8 Open Collectors 
+ LED (fault status) 
+ Modbus Ch.per unit: 8 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 2 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                     D5000 SERIESS  
                                    D5031S 
                                    Hazardous Area: 
Voltage free Contact, 
Proximity Switch 
Line fault detection 
Isolated inputs 
 
Safe Area: 
1 Open Collector 
+ LED (fault status) 
 Ch.per unit: 1 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5030D 
                                    Hazardous Area: 
Voltage free Contact, 
Proximity Switch 
Line fault detection 
Isolated inputs 
 
Safe Area: 
2 SPST (relay contact) 
+ LED (fault status) Ch.per unit: 2 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5020S 
                                    Hazardous Area: 
4-20 mA 
Analog Signal to I/P 
Converters, Electrovalves, 
Actuators and Displays; 
Smart compatible 
 
Safe Area: 
4-20 mA 
Bus powered 
signal from DCS, PLC or other 
control devices. 
Two duplicated outputs. Ch.per unit:1 
Supply: 
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                                                      
                                     
                                     
                                    D5000 SERIESS 
                                    D5212Q 
                                    Hazardous Area: 
4-20 mA 
2-Wires Passive Tx 
 
Safe Area: 
4-20 mA 
+ Modbus Ch.per unit: 4 
Supply:  
20-30 Vdc 
                                    IEC 61511-SIL 3 
                                    
									
																														Other models also available, please contact us for details.									 
                                   
                                  
                                  
                                  
                                       