- Steering Drive:
◦Output for 12V supply: 10V at rated load
◦Max continuous current: 16A
◦Max current for 15 sec.: 20A
◦Max current for 1 sec.: 40A
- Mechanical drive steering: motor Printed rotor with gearbox and electromechanical clutch.
- Hydraulic drive systems: See manufacturers' specs.
- Recommended response times:
◦Hull length up to 11mt: 8 sec. for -20 to +20 deg swing.
◦Hull length 11 to 13m: 10 sec. for -20 to +20 deg swing.
◦Hull length above 13m: 12 sec. for -20 to +20 deg swing.
Other models also available, please contact us for details.
Autopilot SW AP01
UX0AP010SW
- Supply Voltage Range nominal): 12 to 14V dc
- Maximum Supply Voltage Range: 10 to 16V dc
- Supply Current:
◦Basic system in STANDBY: 0.33A
◦Add for Controller 2: 0.15A
◦In Pilot with 20% duty: 2.5A
- Steering Drive:
◦Output for 12V supply: 10V at rated load
◦Output for 24V supply: 22V at rated load
◦Max continuous current 16A
◦Max current for 15 sec.: 20A
◦Max current for 1 sec.: 40A
- Mechanical drive steering: motor Printed rotor with gearbox and electromechanical clutch.
- Torque:
◦12V unit: 120kg-cm at 30 rpm/5A.
◦24V unit: 150kg-cm at 40 rpm/7.5A.
- Hydraulic drive systems: See manufacturers' specs.
- Recommended response times:
◦Hull length up to 11mt: 8 sec. for -20 to +20 deg swing.
◦Hull length 11 to 13m: 10 sec. for -20 to +20 deg swing.
◦Hull length above 13m: 12 sec. for -20 to +20 deg swing.
Other models also available, please contact us for details.
Copyright 2003-2011 (c) Laplace Electric Ltd. ,All rights servered.
Address: Unit C,5/F,Southeast Industrial Building,611-619 Castle Peak Road,Tsuen Wan,N.T. Hong Kong. Tel:852-24131255 Fax:852-24131277 Contacts:Mr. Chris Lau