Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against earth fault with adjustable delay, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR123/P-LSIG In=800A 3p F HR
1SDA055607R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against earth fault with adjustable delay, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR123/P-LSI In=800A 4p F HR
1SDA055614R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit and against selective short circuit, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR123/P-LSI In=800A 3p F HR
1SDA055606R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit and against selective short circuit, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LSIRc In=800A 4p F HR
1SDA058555R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against differential current, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LSIRc In=800A 3p F HR
1SDA058553R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against differential current, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LSIG In=800A 4p F HR
1SDA055613R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against earth fault with adjustable delay, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LSIG In=800A 3p F HR
1SDA055605R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against earth fault with adjustable delay, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LSI In=800A 4p F HR
1SDA055612R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit and against selective short circuit, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LSI In=800A 3p F HR
1SDA055604R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with protection against overload, against instantaneous short-circuit and against selective short circuit, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LI In=800A 4p F HR
1SDA055611R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR122/P-LI In=800A 3p F HR
1SDA055603R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR121/P-LSIG In=800A 4p F HR
1SDA055610R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection and protection against selective short-circuit and earth fault, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR121/P-LSIG In=800A 3p F HR
1SDA055602R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection and protection against selective short-circuit and earth fault, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR121/P-LSI In=800A 4p F HR
1SDA055609R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection and protection against selective short-circuit, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR121/P-LSI In=800A 3p F HR
1SDA055601R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection and protection against selective short-circuit, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR121/P-LI In=800A 4p F HR
1SDA055608R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection, In = 800A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 800 PR121/P-LI In=800A 3p F HR
1SDA055600R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 800A , Electronic trip unit with overload and instantaneous short-circuit protection, In = 800A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 1600 PR123/P-LSIG In=1600A 4p F HR
1SDA055679R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 1600A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against earth fault with adjustable delay, In = 1600A, 4 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.
E1B 1600 PR123/P-LSIG In=1600A 3p F HR
1SDA055671R1
Automatic air circuit-breakers, SACE Emax New E1, Icu 415 V AC = 42kA, Size Iu = 1600A , Electronic trip unit with protection against overload, against instantaneous short-circuit, against selective short circuit and against earth fault with adjustable delay, In = 1600A, 3 poles, Version = Fixed, connection terminal = Horizontal Rear for fixed part
Other models also available, please contact us for details.